SOLVAC S4
Superheated Low Flashpoint Vapor Degreaser
Safely employs all of today’s low-flashpoint solvents such as isopropyl alcohol, acetone, and cyclohexane.
The Solvac Series S4 is a high throughput capacity solution to low-flashpoint solvent precision cleaning applications. A typical process includes immersion in the latest ultrasonic technology with ceramically enhanced transducers that produce unrivaled cleaning with low-flashpoint solvents.
It is ideal for removing residues like films, fingerprints, greases, mold releases, oils, etc. Applications can be found in most industrial facilities.
Two standard tank sizes
Standard tank sizes range from 18″L x 12″W x 12″H to 24″L x 20″W x 18″H.
Model | Overall Dim. (L x W x D) | Tank Size (L x W x D) | Distil- lation Rate (Gal/Hr) | Boiling Heat (kW) | Load Cap. (Gal) | Solv. Cap. (Gal) | Elec. Reqs. | Nitro. Reqs. | Comp. Air Reqs. |
---|---|---|---|---|---|---|---|---|---|
S4- 181212 | 148″ x 48″ x 108″ | 18″ x 12″ x 12″ | 43 | 18 | 1440 | 45 | 480V – 3PH – 30A Secondary: 120V – 1PH – 5A | 20 SCFH @ 80 psig | 1 SCFM @ 80 psig |
S4- 242018 | 180″ x 64″ x 130″ | 24″ x 20″ x 18″ | 70 | 30 | 2880 | 100 | 480V – 3PH – 75A Secondary: 120V – 1PH – 5A | 20 SCFH @ 80 psig | 1 SCFM @ 80 psig |
Standard Features
- TŪV approved and meets all National Fire Protection Standards (NFPA)
- Wash and rinse immersion tanks with patented Crest 40, 58, 132, or 192 kHz ultrasonics
- True SuperheatTM for rapid part drying
- Closed loop hot water heating of solvent and vapor
- High reflux rate
- Recirculation of wash and rinse sump with cartridge filtration
- 100% freeboard ratio to minimize solvent consumption
- Removable panels for easy maintenance access
- Stainless steel condenser and chiller coils to avoid corrosion
- Stainless steel processor tanks with bright annealed finish
- Solvent cool down mode to minimize solvent loss

Safety Features
- Integral CO2 suppression system
- Boiling tank over temperature signal with solvent replacement warning
- Extended freeboard volume
- Boiling tank low-level control
- Vapor level control with reset